C001537_04_CR2 User Manual - 30
Save Settings
The Macro PDF 417 function has the following limitations:
1. You can scan non-MacroPDF417 codes in the middle of a MacroPDF417 file. They will
be uploaded immediately. The incomplete MacroPDF417 segments will be buffered.
2. Scanning a MacroPDF417 code with a file ID different than the MacroPDF417 segments
already stored will cause the stored segments being deleted(aborted) and you will hear
beeps. The new file starts with this code.
3. The CR2 only support up to 16 file segments. When the buffered segments reach 16 and
the file is still not complete, you will hear 3 beeps and all the buffered segments will be
deleted.
4. You can not scan a segment of the same file more than once.
Note: The MacroPDF 417 feature may only be utilized with firmware version 1242 or greater.
4.16 - PDF 417 Symbology
Scan the following codes to enable/disable PDF 417 symbology settings:
PDF 417 On (Default) PDF417 Off Macro PDF 417 On
Macro PDF 417 Off (Default) Sample PDF 417 Code
If your data is encoded into multiple PDF 417 codes, the Macro PDF 417 feature allows a user to scan
these PDF 417 codes and combine the information.
4.17 - Pharmacode
For an explanation of Pharmacode settings and all programming codes please refer to Appendix G of the
CR2 User’s Manual. You may download the Appendix G at:
www.codecorp.com/support/usermanuals.htm