ID-FLX Lite & Telecom Global Guide
113
Setpoint group Engine parameters Related FW 2.5.0
Range [units] 0 .. 600 [s]
Default value 0 s -
Step 1 s
Comm object 15987 Related applications N/A
Description
Defines the shortest time of LBO Preheat activation prior to engine start reached when the measured
temperature is PreheatTemp1 (page 112) or higher. See description of PREHEAT (PAGE 198).
PreheatTime1
6 back to List of setpoints
Setpoint group Engine parameters Related FW 2.5.0
Range [units] PreheatTemp1 (page 112) .. 600 [°C]
Default value 0 °C -
Step -
Comm object 15986 Related applications N/A
Description
Defines the temperature, at which the LBO Preheat activates for the shortest time prior to engine start. See
description of PREHEAT (PAGE 198).
PreheatTemp2
6 back to List of setpoints
Setpoint group Engine parameters Related FW 2.5.0
Range [units] 0 .. 600 [s]
Default value 0 s -
Step -
Comm object 15988 Related applications N/A
Description
Defines the longest time of the LBO Preheat activation prior to engine start reached when the measured
temperature is PreheatTemp2 (page 113) or lower. See description of PREHEAT (PAGE 198).
PreheatTime2
6 back to List of setpoints