Start up
70
HS-RC-C5E-TIN_07.fm
00/0310
OVT POS +
OVT POS -
Axes over-stroke alarm
(positive and negative stroke)
The two OVT POS + and OVT POS - inputs shall be
closed again
Or, with C5G-OTK option installed, the 5 over-stroke
inputs on X3 terminal board shall be closed
Note:
Signals available on X2 connector of the second
AMS-IAM module (a connector serving as plug is
available to close the circuits)
Alternatively, with C5G-OTK option installed, the
signals that shall be closed agian are partly available
on connector by Robot border area and partly available
by the box base on the X3 terminal board close to the
X10 signals connector.
Tab. 8.1 - Circuits and signals to start the C5G
Circuit Description Minimum requirements / Notes