3-61
Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide
Critical Error Log Messages
Continued
Message Description
NMI - PCI Bus Parity Error A parity error was detected on the PCI bus.
NMI - Expansion Board Error A board on the expansion bus indicated an error condition, resulting in a server failure.
NMI - Expansion Bus Master
Time-Out
A bus master expansion board in the indicated slot did not release the bus after its
maximum time, resulting in a server failure.
NMI - Expansion Bus Slave
Time-Out
A board on the expansion bus delayed a bus cycle beyond the maximum time, resulting in a
server failure.
NMI - Fail-Safe Timer
Expiration
Software was unable to reset the system fail-safe timer, resulting in a server failure.
Processor Exception The indicated processor exception occurred.
NMI - Processor Parity Error The processor detected a data error, resulting in a server failure.
Server Manager Failure An error occurred with the Server Manager/R.
NMI - Software Generated
Interrupt Detected Error
Software indicated a system error, resulting in a server failure.
Caution: Temperature
Exceeded
The operating system has detected that the temperature of the system has exceeded the
caution level. Accompanying data in the log notes if an auto-shutdown sequence has been
invoked by the operating system.
Abnormal Program
Termination
The operating system has encountered an abnormal situation that has caused a system
failure.
ASR-2 Test Event The System Configuration Utility generated a test alert.
NMI- Automatic Server
Recovery Timer Expiration
The operating system has received notice of an impending ASR-2 timer expiration.
Required System Fan Failure The required system fan has failed. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
UPS A/C Line Failure
Shutdown or Battery Low
The UPS notified the operating system that the AC power line has failed. Accompanying
data indicates if an auto-shutdown sequence has been invoked or if the battery has been
nearly depleted.
ASR-2 detected by ROM An ASR-2 activity has been detected and logged by the system ROM.

Table of Contents

Other manuals for Compaq ProLiant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq ProLiant 3000 and is the answer not in the manual?

Compaq ProLiant 3000 Specifications

General IconGeneral
BrandCompaq
ModelProLiant 3000
CategoryServer
LanguageEnglish

Related product manuals