DEEP LEARNING PLUS USER MANUAL
38
4. Configure the Enter/Exit Area Detection parameters as desired:
a. Video Source: Select a desired channel for Enter/Exit Area Detection.
b. Name: Enter a custom Enter/Exit Area Detection Trigger preset name.
c. Target Object: Select an object type for detection (person/bike/car). At least one
target object must be selected.
d. Direction: Select the tracking method for detection (enter/exit/both).
e. Advanced Setup: If selected, additional configuration options will appear.
f. Crossing Count: Set the number at which event detection will occur
(e.g., crossing count=1 results in triggering every object detected, crossing count=2
results in triggering every 2nd, 4th, 6th, etc. object detection).
g. Enter Direction Label: Enter a custom label for the on-screen entered objects counter
widget. Note: this label only displays on DL PLUS live video (web/HDMI display output).
h. Exit Direction Label: Enter a custom label for the on-screen exited objects counter
widget. Note: this label only displays on DL PLUS live video (web/HDMI display output).
i. Count Reset: Select a time for resetting the Enter/Exit Area Detection counter, or
manually reset the counter.
5. If desired, import an existing detection rule zone. Or, create a new zone by clicking
and dragging the corners of the yellow box. Clicking within the lines allows for multiple
manipulation points to be created to fit any polygonal area.
6. Click and drag the red widget that will display the Enter/Exit Area Detection trigger count.
7. When all parameters are configured, click <APPLY> to save the settings.

Other manuals for Concept Pro DEEP LEARNING PLUS