- 41 -
-
-
-
N
N
N
N ote
ote
ote
ote
If
If
If
If certain
certain
certain
certain recording
recording
recording
recording is
is
is
is in
in
in
in process,
process,
process,
process, and
and
and
and another
another
another
another parameter
parameter
parameter
parameter demands
demands
demands
demands alarm
alarm
alarm
alarm recording,
recording,
recording,
recording, it
it
it
it will
will
will
will only
only
only
only
be
be
be
be executed
executed
executed
executed after
after
after
after the
the
the
the earlier
earlier
earlier
earlier recording
recording
recording
recording is
is
is
is finished.
finished.
finished.
finished.
Auto
Auto
Auto
Auto recording
recording
recording
recording
The monitor starts the recorder for 8 seconds according to interval time set in the “ TIMING REC TIME ”
of the “ RECORD SETUP ” menu. Refer to C hapter 3 . 4. 8 Recorder Setup for details.
Alarm
Alarm
Alarm
Alarm Recording
Recording
Recording
Recording
Parameter
Parameter
Parameter
Parameter Alarm
Alarm
Alarm
Alarm
The monitor records waveforms 4, 8, or 16 seconds prior to and after the alarm (totally 8, 16 or 32
seconds) (which can be selected in System Menu). All parameter values during the alarm will also be
recorded.
When parameter alarm occurs, two recorded waveforms can be printed out.
In order to avoid repeated printout of alarm waveforms:
If more than two parameter alarms are switched on and triggered simultaneously, the recorder will
print out those of the highest level. If of the same alarm level, the latest alarm will be printed out.
If an alarm occurs during the alarm of another parameter, it will be printed out after the current
recording is finished.
If many alarms occur at the same time, some of waveforms will be stored for printout in turn.
ST
ST
ST
ST Segment
Segment
Segment
Segment Alarm
Alarm
Alarm
Alarm
The monitor records 2-channel ECG waveforms 4, 8, or 16 seconds prior to and after the alarm (totally
8, 16, or 32 seconds) (which can be selected in the ECG SETUP menu ). All parameter values during
the alarm will also be recorded.
Arrhythmia
Arrhythmia
Arrhythmia
Arrhythmia Alarm
Alarm
Alarm
Alarm
The monitor records 2-channel ECG waveforms 4 seconds prior to and after the alarm (totally 8
seconds). All measurement results during the alarm will also be recorded.
Freeze
Freeze
Freeze
Freeze Waveform
Waveform
Waveform
Waveform Recording
Recording
Recording
Recording
The monitor prints out the selected waveforms under the FREEZE mode. In this way you can snap the
abnormal waveforms on the screen and record it.
Trend
Trend
Trend
Trend Graph
Graph
Graph
Graph /
/
/
/ Table
Table
Table
Table Recording
Recording
Recording
Recording
The monitor can print out the trend graph and table in the current TREND GRAPH or TREND TABLE
window.
Arrhythmia
Arrhythmia
Arrhythmia
Arrhythmia Review
Review
Review
Review Recording
Recording
Recording
Recording
The monitor can print out the alarm Arrhythmia event in the current ARR RECALL window.
Alarm
Alarm
Alarm
Alarm Review
Review
Review
Review Recording
Recording
Recording
Recording
The monitor can print out the alarm events include waves and parameters in the current ALARM
RECALL window.
NIBP
NIBP
NIBP
NIBP Review
Review
Review
Review Recording
Recording
Recording
Recording
The monitor can print out all the NIBP review events in NIBP RE CALL window .