10
Entering the User Program/Client Mode
There are 2 levels of program modes, CLIENT mode and INSTALLER mode. Normally the
installer configures the system to give you access to the CLIENT mode so you can add, delete,
or change the user codes. To get into CLIENT mode (provided the system is NOT Armed) Press
<PROGRAM>/
enter Master code then press <ENTER>/ . The Program indicator
lights up to indicate that the system is in User programming mode.
If you get a single long beep at this point and the Program LED doesn’t turn on, it means your
code cannot access Program mode.
How to Exit Program Mode
To exit out of program mode press <PROGRAM>/ and <ENTER>/ . The Program
indicator goes off to indicate that the system is not in User programming mode.
How to Change or Add Codes
About Master Code and the User Code (Using LED Keypad)
The factory default master code (123) is intended as a preliminary control of the alarm system.
After the RUNNER is installed and put into service, the code can be changed to any code known
to the Master user (User-1). The Master user can define up to 100 user codes. To limit access
rights, the holder of the Master code can ask the installer to define several User profiles.
Access rights are listed below:
User code has Area A and/or B permission
User code can Arm and/or Disarm an area
User code can Stay Arm and/or Stay Disarm an area
User code can change its code
User code can change user’s code
User code can Operate control Functions
User code can change dialer telephone numbers
User code can alter the real time clock
User can answer an incoming call and start up/down load
User can allow access to installer program mode from client mode.
Initiate Walk-test mode.
How to Change the Master Code (Using LED Keypad)
NOTE: When changing the Master Code, please Ensure that you remember the new
Master Code that you enter. Otherwise, your systems installer will need to come back
to reset the code. This may incur a Service (Call Out) Fee.
While in CLIENT mode (see “Entering the user Program/Client Mode” above on page-10), Press
<PROGRAM>/
then 1 <ENTER>/ , and 1 <ENTER>/ again. The current
Master Code digits will be flashed back at you one digit at a time. To enter a new Master code,
use the numeric keyboard to enter your new Master code then press <ENTER>/
. The new
Master Code will flash back at you one digit at a time, followed either by three short beeps to
indicate correct entry or one long beep if not accepted. The Master Code can be any
combination of 1 to 6 digits. It is recommended to use at least a 4 digits code but a 6 digit code
will provide greater security.
To exit user Code Program mode, Press <PROG>/
and <ENTER>/ .
How to Add or Change the User Code (Using LED Keypad)
While in CLIENT mode, press <PROGRAM>/ then 1 <ENTER>/ and the User number
(2 to 100) to add or change the code, press <ENTER>/
. If there is an existing code already,
it is flashed back to you. Use the numeric keyboard to enter the new code. The code can hold