21
How to Bypass Zones
Bypass any zone that cannot be Sealed (closed). You can Bypass selected zones prior to arming.
Bypass is also used to temporarily exclude a faulty zone from service, which requires repair.
To bypass a selected zone, press <BYPASS> /
, the ‘Bypass’ indicator lights up to indicate
that the system is in bypass mode.
While in the Bypass mode, it is possible to bypass more than one zone. Enter the zone
number(s) (e.g. 01, 05, 12) for one or more zones you wish to Bypass and Press <ENTER> /
. The Zone number(s) of the Bypassed Zones will be indicated on the LCD Screen.
To reset bypassed zones, press <BYPASS> /
, enter the Zone Number(s) for the zones
you No Longer want bypassed (example, 01, 05), then Press <ENTER> /
to accept this
change. The Zone numbers for the Zones you just Un-Bypassed will turn Off from the LCD
Screen to confirm that the Un-Bypassed zones are N0 Longer Bypassed.
NOTE:
Disarming will Automatically Un-Bypass All Zone other than 24Hr type Zones which require
to be Manually Un-Bypassed.
Using Chime (If enabled at Installation)
A Chime Zone (also called a Day Zone), is a Zone (a Detection Device such as a Magnetic Reed
Switch Contact on (say) a Door) that can Monitor Activity in one part of the building while you
may be elsewhere in the building. If someone (say) Opens the Door that has the ‘Chime’
function Active, then the Chime Zone can be programmed to operate a buzzer or light to let you
know you have a visitor, etc..
To disable the Chime (Day) zone, press and Hold the <Chime> /
button for two
seconds and the LCD Display will indicate that the ‘Chime’ mode is Off. <PROGRAM>, Control
LED indicator lights up to indicate that Chime is disabled.
To Re-Enable the Chime mode, press and Hold the <Chime> /
button for two seconds
and the LCD Display will indicate that the ‘Chime’ mode is On.
Emergency Alerts
This three special keys function is best programmed by your installer to suit your individual
situation. Most commonly it is used in a panic situation.
These are a “PANIC”, “FIRE”, and “MEDICAL” alarm. When using the LED keypad the Panic
alarm can be generated by either the single “Panic” button or by the simultaneous operation of
two buttons. Pressing two buttons simultaneously generates the Fire and Medical alarms
How to initiate a Panic Alarm;
Press simultaneously Buttons < > & < >. Must be Pressed Together
How to initiate a Medical Alarm;
Press simultaneously Buttons < > & < >. Must be Pressed Together.
How to initiate a Fire Alarm
Press simultaneously Buttons < > & < >. Must be Pressed Together.