30
LCD Keypad in Local Edit Mode
The Local Edit Program Mode allows the programming of a customised “System Name” (the
name displayed during idle mode at the keypad), Customised “Zone Names” (the text that
appears on the keypad when a zone is unsealed), Customised “User Names” (the User name is
displayed when viewing arm/disarm events in memory mode), Customised “Area Names” (the
Area name is displayed when viewing arm/disarm events in memory mode) and Customised
“Output Names” (the Output name is displayed when viewing Output On/Off events in memory
mode).
Accessing Local Edit Mode
To enter Local Edit Program Mode on a CROW LCD Keypad Press and Hold <CONTROL>/
followed Immediately by Pressing the <ARM>/
and hold both buttons down for 2
seconds.
NOTE:
You must press and Hold Down the “Control” button first and the “Arm” button must be pressed
Almost at the Same time as the Control button. If you make a mistake, press the “Enter” button and
then repeat the process.
The display now shows “Local Mode kb #” where the # equals the keypad address as
previously set (see “LCD keypad address assignment” on page 19 for details). There are two
ways to program the keypad in “Local Edit Mode”. You can enter in the program location directly
from the list below or you can use the menu function to navigate through all of the program
options. The menus are described on the following pages.
Local Edit Mode Direct Program Addresses
There are a number of program addresses available to you at this time:
[PROG]-[1]-[ENTER] to; ZONE#1 TEXT (maximum 16 characters)
[PROG]-[16]-[ENTER] ZONE#16 TEXT
[PROG]-[800]-[ENTER] UPDATE EDITABLE TEXT TO ALL LCD KEYPADS
[PROG]-[801]-[ENTER] RETURN ALL EDITABLE TEXT TO DEFAULT
[PROG]-[995]-[ENTER] PANEL TYPE
[PROG]-[996]-[ENTER] KEYPAD ADDRESS NUMBER FROM 1-8 CAN BE SET
[PROG]-[997]-[ENTER] KEYPAD LANGUAGE
[PROG]-[998]-[ENTER] AREA IDENTIFYING CHARACTER (assigning numbers or letters to Areas)
[PROG]-[999]-[ENTER] PANEL NAME DISPLAY (maximum 16 characters)
PROG]-[1001]-[ENTER] to; PROGRAM USER “1” NAME
PROG]-[1100]-[ENTER] PROGRAM USER “100” NAME
[PROG]-[2001]-[ENTER] AREA “A” IDENTIFYING NAME (maximum 16 character Area name)
[PROG]-[2002]-[ENTER] AREA “B” IDENTIFYING NAME (maximum 16 character Area name)
PROG]-[3001]-[ENTER] to; PROGRAM OUTPUT “1” NAME
PROG]-[3008]-[ENTER] PROGRAM OUTPUT “8” NAME