3 — PROGRAMMABLE PARAMETERS: Position Feedback Parameters
FEEDBACK DEVICE PARAMETER, cont’d
4 = None. No supervisory position feedback device is connected.
Only a single position feedback device (the primary) is used.
This option is available only for the Supervision Feedback Device
parameter. Using this setting may make the system non-
compliant with EN 13849, and must be evaluated by the OEM.
When the Supervision Feedback Device is set to 4, wheel
position supervision is disabled. This option is provided to allow
systems not compliant with EN 13849 to be set up without having
to supply connections to the supervisory inputs from the single
primary feedback device.