68 D50 PLC User's Manual
Example
Program Expression Time Chart
R000.0
0.7 sec
TC12
R000.1
7 sec
TC200
R000.0
R000.1
TC012
TC200
TIM
T CH = 12
SV = 70
SST
T CH = 200
SV = 70
M11.5
(OUT)
M22.5
(OUT)