Recommended Action
None.
Revision
1
Parameters
peer
Context Parameters
ALG Module Name
ALG Session ID
Connection
2.1.98. failed_to_register_rawconn (ID: 00200238)
Default Severity
ERROR
Log Message
FTPALG: Internal Error - failed to register eventhandler. Closing
connection
Explanation
An internal error occured when registering an eventhandler, and the
connection will be closed.
Gateway Action
close
Recommended Action
Contact the support.
Revision
1
Context Parameters
ALG Module Name
2.1.99. failed_to_merge_conns (ID: 00200239)
Default Severity
ERROR
Log Message
FTPALG: Internal Error - failed to merge conns. Closing connection
Explanation
An internal error occured when two connections were being merged
into one, and the connection will be closed.
Gateway Action
close
Recommended Action
Contact the support.
Revision
1
Context Parameters
ALG Module Name
2.1.100. max_ftp_sessions_reached (ID: 00200241)
Default Severity
WARNING
Log Message
FTPALG: Maximum number of FTP sessions (<max_sessions>) for
service reached. Closing connection
Explanation
The maximum number of concurrent FTP sessions has been reached
for this service. No more sessions can be opened before old sessions
have been released.
Gateway Action
close
2.1.98. failed_to_register_rawconn
(ID: 00200238)
Chapter 2. Log Message Reference
75

Table of Contents

Other manuals for D-Link NetDefend DFL-210

Related product manuals