xStack
®
DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide
96
cir - Specify the Committed Information Rate. The unit is in Kbps. CIR should always be equal
or less than PIR.
<value 1-1048576> - Enter the commited information rate value here. This value must be
between 1 and 1048576.
cbs - (Optional) Specify the “Committed Burst Size”. The unit is Kbytes. That is to say, 1
means 1Kbytes. This parameter is an optional parameter. The default value is 4*1024.
<value 1-262144> - Enter the commited burst size value here. This value must be between
1 and 262144.
pir - Specify the “Peak Information Rate”. The unit is in Kbps. PIR should always be equal to
or greater than CIR.
<value 1-1048576> - Enter the peak information rate value here. This value must be
between 1 and 1048576.
pbs - (Optional) Specify the “Peak Burst Size”. The unit is in Kbytes. This parameter is an
optional parameter. The default value is 4*1024.
<value 1-262144> - Enter the peak burst size value here. This value must be between 1
and 262144.
color_blind - (Optional) Specify the meter mode as color-blind. The default is color-blind
mode.
color_aware - (Optional) Specify the meter mode as color-aware. The final color of the packet
is determined by the initial color of the packet and the metering result.
conform - (Optional) Specify the action when a packet is mapped to the “green” color.
permit - Permits the packet.
replace_dscp - Changes the DSCP of the packet.
<value 0-63> - Enter the replace DSCP value here. This value must be between 0 and
63.
counter - (Optional) Specify the ACL counter. This is optional. The default is “disable”. The
resource may be limited so that a counter cannot be turned on. Counters will be cleared
when the function is disabled.
enable - Specify that the ACL counter option will be enabled.
disable - Specify that the ACL counter option will be disabled.
exceed - Specify the action when a packet is mapped to the “yellow” color.
permit - Permits the packet.
replace_dscp - (Optional) Changes the DSCP of the packet.
<value 0-63> - Enter the replace DSCP value here. This value must be between 0 and
63.
drop - Drops the packet.
counter - (Optional) Specify the ACL counter. This is optional. The default is “disable”. The
resource may be limited so that a counter cannot be turned on. Counters will be cleared
when the function is disabled.
enable - Specify that the ACL counter option will be enabled.
disable - Specify that the ACL counter option will be disabled.
violate - Specify the action when a packet is mapped to the “red” color.
permit - Permits the packet.
replace_dscp - (Optional) Changes the DSCP of the packet.
<value 0-63> - Enter the replace DSCP value here. This value must be between 0 and
63.
drop - Drops the packet.
counter - (Optional) Specify the ACL counter. This is optional. The default is “disable”. The
resource may be limited so that a counter cannot be turned on. Counters will be cleared
when the function is disabled.
enable - Specify that the ACL counter option will be enabled.
disable - Specify that the ACL counter option will be disabled.
delete - Deletes the specified flow_meter.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.