EasyManua.ls Logo

D-Link X-STACK DES-3200 SERIES - Page 581

D-Link X-STACK DES-3200 SERIES
647 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
xStack
®
DES-3200 Series Layer 2 Managed Fast Ethernet Switch CLI Reference Guide
577
local5 | local6 | local7] | udp_port <udp_port_number> | ipaddress <ipaddr> | state [enable |
disable]}
Parameters
<index> - Enter the host index value here.
all - Specify that all the host indexes will be used.
severity - (Optional) Specify the severity level.
emergency - Severity level 0
alert - Severity level 1
critical - Severity level 2
error - Severity level 3
warning - Severity level 4
notice - Severity level 5
informational - Severity level 6
debug - Severity level 7
<level 0-7> - Enter the severity level value here. This value must be between 0 and 7.
facility - (Optional) Some of the operating system daemons and processes have been assigned
Facility values. Processes and daemons that have not been explicitly assigned a Facility may
use any of the "local use" facilities or they may use the "user-level" Facility. Those Facilities
that have been designated are shown below. This facility setting will be put in the syslog
packet when it is sent to a specific syslog server.
local0 - Specify that the user-defined facility will be set to local 0.
local1 - Specify that the user-defined facility will be set to local 1.
local2 - Specify that the user-defined facility will be set to local 2.
local3 - Specify that the user-defined facility will be set to local 3.
local4 - Specify that the user-defined facility will be set to local 4.
local5 - Specify that the user-defined facility will be set to local 5.
local6 - Specify that the user-defined facility will be set to local 6.
local7 - Specify that the user-defined facility will be set to local 7.
udp_port - (Optional) Specify the UDP port number.
<udp_port_number> - Enter the UDP port number used here.
ipaddress - (Optional) Specify IP address for the host.
<ipaddr> - Enter the IP address used for the configuration here.
state - (Optional) The syslog protocol is used for the transmission of event notification messages
across networks to a host. The option enables or disables the host to receive such messages.
enable - Specify that the host to receive such messages will be enabled.
disable - Specify that the host to receive such messages will be disabled.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the syslog host configuration:
DES-3200-28P:admin#config syslog host all severity debug facility local0
Command: config syslog host all severity debug facility local0
Success.
DES-3200-28P:admin#