Table 7.9.1 - Bus Bars Supply Configurations
Switches Buses are powered by
Crash
lever
SOUR
CE
GENE
RATO
R
ESS
BUS
TIE
BATT
BUS
ESS
BUS 1
ESS
BUS 2
BUS 1
T
O 5
UP BATT OFF NORM Battery Battery Battery Battery
UP BATT MAIN NORM
Battery
&
MAIN
Battery
&
MAIN
Battery
&
MAIN
Battery
&
MAIN
(*)
UP BATT ST-BY NORM
Battery
& ST-
BY
Battery
& ST-
BY
Battery
& ST-
BY
Battery
& ST-
BY
(*)
UP OFF MAIN NORM MAIN MAIN MAIN MAIN
UP OFF ST-BY NORM ST-BY ST-BY ST-BY ST-BY
UP BATT OFF EMER Battery Battery Battery None
(*) In that case, power is done by MAIN or ST-BY and battery is used as a
floated battery.
Section 7
Description
Pilot's Information Manual
PIM TBM 960 - Edition 0
Rev. 02
Page 7.9.3
PIM - DO NOT USE FOR FLIGHT OPERATIONS