3 | Specific installer safety instructions
Installer reference guide
17
ERLA11~16D + EBBH/X11+16D
Daikin Altherma 3 R W
4P643603-1B – 2022.05
Opening and closing the units (see
"7.2Opening and closing the units"[
4
80]
)
DANGER: RISK OF ELECTROCUTION
Do NOT leave the unit unattended when the service cover is removed.
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
Mounting the outdoor unit (see
"7.3Mounting the outdoor unit"[
4
83]
)
WARNING
Fixing method of the outdoor unit MUST be in accordance with the instructions from
this manual. See "7.3Mounting the outdoor unit"[483].
Mounting the indoor unit (see
"7.4Mounting the indoor unit"[
4
87]
)
WARNING
Fixing method of the indoor unit MUST be in accordance with the instructions from
this manual. See "7.4Mounting the indoor unit"[487].
Piping installation (see
"8Piping installation"[
4
90]
)
WARNING
The field piping method MUST be in accordance with the instructions from this
manual. See "8Piping installation"[490].
DANGER: RISK OF BURNING/SCALDING
CAUTION
Incomplete flaring may cause refrigerant gas leakage.
Do NOT re-use flares. Use new flares to prevent refrigerant gas leakage.
Use flare nuts that are included with the unit. Using different flare nuts may
cause refrigerant gas leakage.
WARNING
Provide adequate measures to prevent that the unit can be used as a shelter by small
animals. Small animals that make contact with electrical parts can cause
malfunctions, smoke or fire.

Table of Contents

Other manuals for Daikin Altherma 3 R W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma 3 R W and is the answer not in the manual?

Daikin Altherma 3 R W Specifications

General IconGeneral
TypeAir-to-water heat pump
RefrigerantR-32
Energy Efficiency Class (Heating)A+++
Energy Efficiency Class (Cooling)A++
Operating Temperature Range (Heating)-25°C to 35°C
Operating Temperature Range (Cooling)10°C to 46°C
Heating Capacity4.0 - 16.0 kW
Sound Power Level62 dBA

Related product manuals