5 | About the units and options
Installer reference guide
31
ERLA11~16D + EBBH/X11+16D
Daikin Altherma 3 R W
4P643603-1B – 2022.05
5.2.4 Possible combinations of indoor unit and domestic hot water tank
Combination table
Indoor unit Domestic hot water tank
EKHWS*D* EKHWSU*D* EKHWP* Third-party
tank
EBBH/X O O O O
(a)
(a)
When using a third-party tank, make sure it complies with the minimum requirements (see
"Third-party tank requirements"[431]).
Third-party tank requirements
In case of a third-party tank, the tank shall adhere to the following requirements:
The heat exchanger coil of the tank is ≥1.05m² and ≤3.7m².
The tank thermistor must be located above the heat exchanger coil.
The booster heater must be located above the heat exchanger coil.
NOTICE
Performance. Performance data for third-party tanks CANNOT be provided, and
performance CANNOT be guaranteed.
If you have a tank in which you can insert a thermistor, use connection kit
EKHY3PART. For detailed installation instructions, see the installation manual of the
connection kit and the addendum book for optional equipment.
a
b
a Indoor unit
b Tank