3 | Specific installer safety instructions
Installer reference guide
16
ERLA11~16D + EBBH/X11+16D
Daikin Altherma 3 R W
4P643603-1B – 2022.05
3 Specific installer safety instructions
Always observe the following safety instructions and regulations.
Handling the unit (see
"4.1.1To handle, unpack and remove accessories –
Outdoor unit"[
4
22]
)
CAUTION
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit.
Application guidelines (see
"6Application guidelines"[
4
32]
)
CAUTION
If there is more than one leaving water zone, ALWAYS install a mixing valve station in
the main zone to decrease (in heating)/increase (in cooling) the leaving water
temperature when the additional zone has demand.
Installation site (see
"7.1Preparing the installation site"[
4
66]
)
WARNING
Follow the service space dimensions in this manual for correct installation of the unit.
Outdoor unit: See "17.1Service space: Outdoor unit"[4290].
Indoor unit: See "7.1.3Installation site requirements of the indoor unit"[469].
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
WARNING
DO NOT reuse refrigerant piping that has been used with any other refrigerant.
Replace the refrigerant pipes or clean thoroughly.
Special requirements for R32 (see
"7.1.4Special requirements for R32
units"[
4
70]
)
WARNING
Do NOT pierce or burn refrigerant cycle parts.
Do NOT use means to accelerate the defrosting process or to clean the
equipment, other than those recommended by the manufacturer.
Be aware that R32 refrigerant does NOT contain an odour.
WARNING
The appliance shall be stored so as to prevent mechanical damage and in a well-
ventilated room without continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric heater).
WARNING
Make sure installation, servicing, maintenance and repair comply with instructions
from Daikin and with applicable legislation and are executed ONLY by authorised
persons.

Table of Contents

Other manuals for Daikin Altherma 3 R W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma 3 R W and is the answer not in the manual?

Daikin Altherma 3 R W Specifications

General IconGeneral
TypeAir-to-water heat pump
RefrigerantR-32
Energy Efficiency Class (Heating)A+++
Energy Efficiency Class (Cooling)A++
Operating Temperature Range (Heating)-25°C to 35°C
Operating Temperature Range (Cooling)10°C to 46°C
Heating Capacity4.0 - 16.0 kW
Sound Power Level62 dBA