15 | Troubleshooting
Installer reference guide
277
ERLA11~16D + EBBH/X11+16D
Daikin Altherma 3 R W
4P643603-1B – 2022.05
15.4.1 To display the help text in case of a malfunction
In case of a malfunction, the following will appear on the home screen depending
on the severity:
▪ : Error
▪ : Malfunction
You can get a short and a long description of the malfunction as follows:
1 Press the left dial to open the main menu and go to
Malfunctioning.
Result: A short description of the error and the error code is
displayed on the screen.
2 Press in the error screen.
Result: A long description of the error is displayed on the
screen.
15.4.2 Error codes: Overview
Error codes of the unit
Error code Description
7H-01 Water flow problem
7H-04 Water flow problem during domestic hot water
production
7H-05 Water flow problem during heating/sampling
7H-06 Water flow problem during cooling/defrost
7H-07 Water flow problem. Pump deblocking active
7H-08 Pump abnormality during operation (pump
feedback)
80-00 Returning water temperature sensor problem
81-00 Leaving water temperature sensor problem
81-01 Mixed water thermistor abnormality.
81-06 Entering water temperature thermistor
abnormality (indoor unit)
89-01 Heat exchanger freeze-up protection activated
during defrost (error)
89-02 Heat exchanger freeze-up protection activated
during heating / DHW operation. (warning)
89-03 Heat exchanger freeze-up protection activated
during defrost (warning)
89-05 Heat exchanger freeze-up protection activated
during cooling operation. (error)
89-06 Heat exchanger freeze-up protection activated
during cooling operation. (warning)
8H-00 Abnormal increase outlet water temperature