7 | Unit installation
Installer reference guide
88
ERLA11~16D + EBBH/X11+16D
Daikin Altherma 3 R W
4P643603-1B – 2022.05
2×
30.530.5
220
220
(mm)(mm)
112.5112.5
a
a Optional: If you want to fix the unit to the wall from inside the unit, provide an
additional screw plug.
2 Lift the unit.
11 kW: 52.5 kg
16 kW: 54.5 kg
3 Attach the unit to the wall bracket:
▪ Tilt the top of the unit against the wall at the position of the wall bracket.
▪ Slide the bracket on the back of the unit over the wall bracket. Make sure
the unit is fixed properly.
4 Optional: If you want to fix the unit to the wall from inside the unit:
▪ Remove the upper front panel, and open the switch box. See "7.2.4To open
the indoor unit"[481].
▪ Remove the EPP block.
▪ Fix the unit to the wall with an Ø8mm screw.
▪ Reattach the EPP block.