Daikin LXE10E136 - Chilled Mode

Daikin LXE10E136
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Component name Pull-down
Capacity
Heat-up
Overcool
control protection
Compressor CC ON ON ON OFF
Evaporator fan. High speed EFH ON ON ON ON
Evaporator fan. Low speed EFL OFF OFF OFF OFF
Condenser fan CF ON / OFF1 ON ON / OFF4 OFF
Liquid solenoid valve LSV ON ON OFF OFF
Economizer solenoid valve ESV ON OFF OFF OFF
Injection solenoid valve ISV ON / OFF2 ON / OFF5 ON / OFF3 OFF
Hot-gas solenoid valve HSV OFF ON / OFF5 ON OFF
Defrost solenoid valve DSV OFF ON / OFF5 ON OFF
Discharge gas by-pass solenoid valve
BSV OFF ON / OFF5 OFF OFF
Reheat solenoid valve RSV ON / OFF6 OFF OFF OFF
Suction modulating valve SMV
100% 3 to 100% 100% 100%
Electronic expansion valve EV
21~420pls (5~100%)
48~420pls (11~100%)
0pls (0%) 189pls (45%)
2-19
2.5.2 Chilled mode
Control state transition and common control
START
SS<SP+1.5˚CSSSP+1.5˚C
Overcool protection
Capacity control
Pull-down
Heat-up
SS : Control temperature (supply air sensor)
SP: Set point temperature
SS<SP+1.5˚C RSSP+1.0˚C Without dehumidification:
RSSP+1.0˚C
With dehumidification
RSSP+2.0˚C
SS>SP+5.0˚C
SSSP+1.0˚C
and 3-minutes
elapse
(SSSP–3.0˚C
and 3-minutes elapse)
or (
SSSP–0.5˚C
and 30-minutes elapse)
SSSP–0.5˚C and 3-minutes elapse
Magnetic
contactor
Operation of magnetic contactor and solenoid valve
Note) 1: High pressure control 4: Release control
2: Injection control 5: Capacity control and hot gas by-pass
3: Charge control 6: RSVOFF RS20˚CRSVON RS25˚C
Solenoid valve
02LXE10E100(16-28)E.qx08.8.134:40PMページ2-19