3-6
※1.
Current indication mode (indication of operation conditions)
Page 3-8
Indicates the unit operation conditions.
●Supply air temperature (SS)
●Return air temperature (RS)
●Defrost interval
●Alarm
●
Setting point humidity and humidity (optional)
※2. Operation setting mode
Page 3-9
Settings for cargo transportation
●Temperature settings
●Defrost interval settings
●Humidity settings (optional)
※3.
Battery mode (settings for operation conditions by using the battery)
Page 3-10
Setting can be executed when
commercial power supply is not available.
●Temperature settings
●Humidity settings
●Defrost interval settings
●Unit ON/OFF setting
※4. Mode operation
Page 3-11
q G-Set operation : The maximum power consumption can be set in case of operation
by generation.
w Automatic pump down
: The pump down can be executed automatically.
e Mode Operation
: Dehumidification mode can be set. (optional)
※5. LED display off mode
Page 3-12
LED display section on the controller can
be turned off.
●LED lights off
●Return air temperature (RS)
●Pulp temperature (USDA #1, #2, #3)
●Cargo temperature (CTS)
●
Data recorder supply air temperature (DSS)
●
Data recorder return air temperature (DRS)
※6. Sensor indication mode
Page 3-13
Each sensor value can be indicated.
●Discharge gas temperature (DCHS)
●Suction gas temperature (SGS)
●Modulating valve opening
●Electronic expansion valve opening
●Supply air temperature (SS)
●High pressure (HPT)
●Low pressure (LPT)
●Total current (CT1)
●Compressor current (CT2)
●Voltage (PT1)
●Ambient temperature (AMBS)
●Evaporator inlet temperature (EIS)
※7. Temperature record scroll function
Page 3-16
Temperature record of the control sensor
can be indicated in the order (scroll
indication) from the latest data.
●Chilled mode: Supply air temperature
(up to 7 days)
●Frozen mode: Return air temperature
●Evaporator outlet temperature (EOS)
[optional]