Setpoint 1 [unit] (SETPOINT 1 [UNITS]) [11]
Setpoint 2 [unit] (SETPOINT 2 [UNITS]) [12]
Feedback 1 (FEEDBACK 1 [UNITS]) [13]
Feedback 2 (FEEDBACK 2 [UNITS]) [14]
Feedback [unit] (FEEDBACK [UNITS]) [15]
Motor voltage [V] (MOTOR VOLTAGE [V]) [16]
DC link voltage [V] (DC VOLTAGE [V]) [17]
Thermal load, motor [%]
(THERM.MOTOR LOAD [%]) [18]
Thermal load, VLT [%]
(THERM.DRIVE LOAD [%]) [19]
Digital input [Binary code]
(DIGITAL INPUT [BIN]) [20]
Analogue input 53 [V] (ANALOG INPUT 53
[V]) [21]
Analogue input 54 [V] (ANALOG INPUT 54
[V]) [22]
Analogue input 60 [mA]
(ANALOG INPUT 60 [mA]) [23]
Relay status [binary code] (RELAY STA-
TUS) [24]
Pulse reference [Hz] (PULSE REFERENCE
[HZ]) [25]
External reference [%] (EXT. REFERENCE
[%]) [26]
Heat sink temp. [°C] (HEATSINK TEMP [°C]) [27]
Communication option card warning
(COMM OPT WARN [HEX]) [28]
LCP display text (FREE PROG.ARRAY) [29]
Status word (STATUS WORD [HEX]) [30]
Control word (CONTROL WORD [HEX]) [31]
Alarm word (ALARM WORD [HEX]) [32]
PID output [Hz] (PID OUTPUT [HZ]) [33]
PID output [%] (PID OUTPUT [%]) [34]
Real Time Clock (REAL TIME CLOCK) [40]
Function:
This parameter allows a choice of the data value to be
shown in the display, line 2, when the frequency con-
verter is turned on. The data values will also be inclu-
ded in the display mode scroll-list. Parameters
008-010 Small display readout allow a choice of anoth-
er three data values, shown in line 1.
See the description of the control unit.
Description of choice:
No readout can only be selected in parameters
008-010 Small display readout.
Resulting reference [%] gives a percentage for the
resulting reference in the range from Minimum refer-
ence, Ref
MIN
to Maximum reference, Ref
MAX
. See also
reference handling.
Reference [unit] gives the resulting reference in Hz in
Open loop. In Closed loop, the reference unit is selec-
ted in parameter 415 Process units.
Frequency [Hz] gives the output frequency from the
frequency converter.
% of maximum output frequency [%] is the present
output frequency as a percentage value of parameter
202 Output frequency high limit, f
MAX
.
Motor current [A] states the phase current of the mo-
tor measured as effective value.
Power [kW] states the actual power consumed by the
motor in kW.
Power [HP] states the actual power consumed by the
motor in HP.
Output energy [kWh] states the energy consumed
by the motor since the latest reset was made in pa-
rameter 618 Reset of kWh counter.
Hours run [Hours] states the number of hours that the
motor has run since the latest reset in parameter
619 Reset of hours-run counter.
User -defined readout [-] is a user-defined value, cal-
culated on the basis of the present output frequency
and unit, as well as the scaling in parameter 005 Max.
value of user-defined readout. Select unit in parameter
006 Unit for user-defined readout.
Setpoint 1 [unit] is the programmed setpoint value in
parameter 418 Setpoint 1. The unit is decided in pa-
rameter 415 Process units . See also Feedback han-
dling.
Setpoint 2 [unit] is the programmed setpoint value in
parameter 419 Setpoint 2. The unit is decided in pa-
rameter 415 Process units.
Feedback 1 [unit] gives the signal value of the result-
ing feedback 1 (Term. 53). The unit is decided in
parameter 415 Process units. See also Feedback han-
dling .
Feedback 2 [unit] gives the signal value of the result-
ing feedback 2 (Term. 53). The unit is decided in
parameter 415 Process units.
Feedback [unit] gives the resulting signal value using
the unit/scaling selected in parameter 413 Minimum
feedback, FB
MIN
, 414 Maximum feedback, FB
MAX
and
415 Process units .
Motor voltage [V] states the voltage supplied to the
motor.
DC link voltage [V] states the intermediate circuit
voltage in the frequency converter.
VLT
®
6000 HVAC Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
MG.61.B5.02 - VLT
®
is a registered Danfoss trademark 103
Programming