Page 94
MS-01429 Mag Stripe Data
Data sent to a track does not match the requirements
for that track.
Possible Cause 1: Data sent uses a different encoding format than the one
set for the track.
Solution 1: Determine the magnetic stripe formats for the tracks you use.
Change the encoding format(s) in the application so it is set to the same
format as the track(s), make sure the data characters are allowed for the
track(s), and resend the print job.
Possible Cause 2: Data sent uses an encoding format that is not supported
by the magnetic stripe module.
Solution 2: Determine the magnetic stripe formats for the tracks you use.
Change the encoding format(s) in the application so it is set to the same
format as the track(s), make sure the data characters are allowed for the
track(s), and resend the print job.
The magnetic stripe module and cards must be capable of accepting and
encoding each track of data the application sends.
If you cannot fix the problem, contact your service provider for assistance.