52 Printer Manager
Changethesettingsasneeded,andthenclickSetCurrenttoapplythechanges.
Attempts—Specifythenumberofattempts(automaticretries)theprintermakestoencode
themagneticstripedata.Thisvaluealsoisusedforthenumberoftimestoattempttoread
magneticstripedata.
Ifyousetthisnumbertoalowervalue,itincreasesthethroughputoftheprinterbutcan
decreasethereliabilityofmagneticstripeencoding.
Ifyousetthenumbertoa highervalue,itdecreasesthethroughputoftheprinterbutcan
increasethereliabilityofmagneticstripeencoding.
Avalueof1meansnoretryattempts.
Coercivity—Selectthecoercivitysettingthatmatchesthecardsyouareusing.Coercivity
measurestheresistanceofmagneticmaterialtotheremovalofencodeddata.High
coercivity(HICO)requiresmoreelectricalforcetoencodedataandthedataismoreresistant
tomagneticinterference.ThechoicesareHICO,LOCO,NTT1,
NTT2,NTT3.
DataFormat(1,2,3)—Specifythenamesofthedataformatsusedfortracks1,2,and3.
Forsingle‐trackmagneticstripeencoding,setDataFormat1toJISandDataFormat2and
DataFormat3toNONE.
Touseacustomdataformat,definetheformatsfortracks1,2,and/or3usingthe
MagStripeCustomTrack(1,
2,3)settingsandthensetthecorrespondingDataFormatsettings
toCUSTOM.
NoDataDisableTrack—Disablethemagneticstripewritehea dforatrackifthetrackcontains
nodata.Whenthisisdisabled,anytrackthatwasnotgivendataiserased.
ReadT r ack(1,2,3)—Allowmagneticstripereadactionstoreadfromtr acks1,2,and3.
SSA(1,2,3)—Adjustthestartsentinelpositionfortracks1,2,and3.(SSA3alsosetsthestart
sentinelforasingletrack.)Thestartsentinelisencodedonthemagneticstripeimmediately
beforethefirstdatacharacterandindicatesthebeginningofdata.Enteravaluefrom‐4to
4.
WriteTrack(1,2,3)—Allowmagneticstripewriteactionstowritetotracks1,2,and3.