EasyManuals Logo

Datalogic Gryphon 2D Series User Manual

Datalogic Gryphon 2D Series
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
LED AND BEEPER INDICATORS ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
109
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following
a good read. The good read LED on time can be set within a range of 100 milliseconds to
25,500 milliseconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps
the LED on until the next trigger pull.
See
page 290 in “References” for detailed instructions and examples for setting this fea-
ture.
$CLAGL00
Good Read LED Duration Setting =
Keep LED on until next trigger pull
Select Good Read LED Duration Setting
$CLAGL
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
003 = Good Read LED stays on for 300 msec.
NOTE: Indicators are dimmed during sleep.

Table of Contents

Other manuals for Datalogic Gryphon 2D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon 2D Series and is the answer not in the manual?

Datalogic Gryphon 2D Series Specifications

General IconGeneral
BrandDatalogic
ModelGryphon 2D Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals