STANDARD 2 OF 5 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
165
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for "Standard 2 of 5 Length Control" on
page 164
. Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. The length includes the bar code’s check and data
characters.
The length can be set from 1 to 50 characters. See "
Set Length 1" on page 293 for more
detailed programming instructions.
Standard 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for "Standard 2 of 5 Length Control" on
page 164
. Length 2 is the maximum label length if in Variable Length Mode, or the sec-
ond fixed length if in Fixed Length Mode. The length includes the bar code’s check and
data characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this
length (only one fixed length). See "
Set Length 2" on page 294 for more detailed pro-
gramming instructions.
Select Standard 2 of 5 Length 1 Setting
$CS2L1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 08 (8 characters)
Select Standard 2 of 5 Set Length 2 Setting
$CS2L2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)

Table of Contents

Other manuals for Datalogic Gryphon 2D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon 2D Series and is the answer not in the manual?

Datalogic Gryphon 2D Series Specifications

General IconGeneral
BrandDatalogic
ModelGryphon 2D Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals