CODE 128 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
151
Code 128 Set Length 1
This feature specifies one of the bar code lengths for "Code 128 Length Control" on page
150
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed
length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 80 characters. See "
Set Length 1" on page 293 for more
detailed programming instructions.
Code 128 Set Length 2
This feature specifies one of the bar code lengths for "Code 128 Length Control" on page
150
. Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed length if in Fixed Length Mode. Length includes the bar code’s data characters
only.
The length can be set from 1 to 80 characters. A setting of 00 specifies to ignore this
length (only one fixed length). See "
Set Length 2" on page 294 for more detailed pro-
gramming instructions.
Select Code 128 Set Length 1 Setting
$CC8L1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select Code 128 Set Length 2 Setting
$CC8L2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 80 (80 characters)

Table of Contents

Other manuals for Datalogic Gryphon 2D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon 2D Series and is the answer not in the manual?

Datalogic Gryphon 2D Series Specifications

General IconGeneral
BrandDatalogic
ModelGryphon 2D Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals