ENTER/EXIT PROGRAMMING MODE SYMBOLOGIES
134
GRYPHON™ I GD/GBT/GM4200
Code 39 Full ASCII
In Code 39 decoding, this enables/disables the translation of Code 39 characters to
Code 39 full-ASCII characters.
Code 39 Quiet Zones
This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are
blank areas at the ends of a bar code and are typically 10 times the width of the narrow
-
est bar or space in the label.
$CC3FA00
Code 39 Full ASCII = Disable
Code 39 Full ASCII = Enable
$CC3FA01
$CC3LO01
Code 39 Quiet Zones = Quiet Zone on one side
Code 39 Quiet Zones = Quiet Zones on two sides
$CC3LO02
$CC3LO03
Code 39 Quiet Zones = Auto
Code 39 Quiet Zones = Virtual Quiet Zones on two sides
$CC3LO04
$CC3LO05
Code 39 Quiet Zones =
Small Quiet Zones on two sides