Enter/Exit Programming Mode1D Code Selection
148
Gryphon™ I GD44XX/GBT4400/GM440X
Code 39 Start/Stop Character Transmission
Enable this option to enable/disable transmission of Code 39 start and stop
characters
DEFAULT
$CC3SS00(CR)
Code 39 Start/Stop Character Transmission =
Don’t Transmit
$CC3SS01(CR)
Code 39 Start/Stop Character Transmission = Transmit
.
Code 39 Full ASCII
Enables/disables the translation of Code 39 characters to Code 39 full-ASCII
characters.
DEFAULT
$CC3FA00(CR)
Code 39 Full ASCII = Disable
$CC3FA01(CR)
Code 39 Full ASCII = Enable