Loading...
Enter/Exit Programming Mode
266
Gryphon™ I GD44XX/GBT4400/GM440X
Power Off
See “” on page 27 for information about this BT feature.
Powerdown Timeout
The Powerdown Timeout feature sets the time for automatically switching
the unit off when the imager has been idle.
$CSLPS00(CR)
Powerdown Timeout = Disable
$CSLPS01(CR)
Powerdown Timeout = 10 minutes
$CSLPS02(CR)
Powerdown Timeout = 20 minutes
R)$CSLPS03(CR
)
Powerdown Timeout = 30 minutes
DEFAULT
DEFAULT
$CSLPS06(CR)
Powerdown Timeout = 60 Minutes (1 Hour)
$CSLPS0C(CR)
Powerdown Timeout = 120 Minutes (2 Hours)