Item Description
User
Environment
GD44XX Models GBT Models
Operating
Temperature
32° to 131° F (0° to
55° C)
32° to 122° F (0° to 50° C)
Charging Tem-
perature
N/A 32° to 104° F (0° to 40° C)
Storage Tem-
perature
-4° to 158° F (-20° to 70° C)
Humidity Operating: 5% to 90% relative humidity, non-condensing
Drop Specifica-
tions
Scanner withstands 18 drops from 1.8 meters
(5.9 feet) to concrete
Ambient Light
I
mmunity
Up to 100,000 Lux
Contaminants
Spray/Rain/
Dust/Particu-
lates
IEC 529-IP52
ESD Level 16 KV
Regulatory
Electrical
Safety
UL 60950, CSA C22.2 No. 60950, IEC 60950
EMI/RFI
GD44XX Models GBT Models
GM44 433 Models
North America (FCC) :
Part 15 Class B; Canada
( IC) : ICES-003 Class B;
Russia ( Gost); Euro-
pean Union EMC Direc-
tive; VCCI-Japan;
Korean KCC;
Taiwan
EMC (BSMI);
Australia (ACMA)
Europe - CE; Australia
- C-
tick; Russia –
GOST; USA/CANADA –
FCC/IC; Japan – JRF/
VCCI; Mexico - NOM +
Cofetel; South Korea -
KCC; Brazil - ANATEL;
Argentina - CNC;
China - SRRC; Malay-
sia - SIRIM; Indonesia,
Singapore - IDA;
Tai-
wan - NCC; Philippines
- N
TC
Europe - CE; Australia
- C
-tick; Russia –
GOST; Singapore - IDA;
China - SRRC; Brazil -
ANATEL
GM44 910 Models
USA/CANADA – FCC/
IC; Mexico - NOM +
Cofetel;
Laser Safety
IEC Class 2
Radiation 1 mW Avg., Emitted wavelength 650 nm, 12ms pulse, Beam
Di
vergence 8.4 deg x 8.1 deg ("plus" pattern).
Complies with FDA performance standards for laser products except for
devi
ations pursuant to Laser Notice No. 50, dated June 24, 2007.