EasyManuals Logo

Datalogic PowerScan PBT9500 User Manual

Datalogic PowerScan PBT9500
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #291 background imageLoading...
Page #291 background image
Scanning Features
Product Reference Guide
281
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON
state once the state is entered. The range for this setting is from 1 to 255
seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0
= 000
,
5 = 005, 20 = 020, etc.
3. Go to
page 74 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE
TIME SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix D, Key-
pad
, that represent the duration which was determined in the steps
above. You will hear a two-beep indica
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
Table 41 for some examples of how to
set this feature.
Table 41. Scanning Active Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25
min.)
2 Pad leading zero(es)
001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan Three Characters
From
Appendix D,
Keypad
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic PowerScan PBT9500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PBT9500 and is the answer not in the manual?

Datalogic PowerScan PBT9500 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength680 nm
Sensor typeLaser
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle0 - 40 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supported-
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, MaxiCode, Micro QR Code, QR Code
Battery life10 h
Charging time4 h
Battery capacity2150 mAh
Power source typeBattery
Number of reads per charge30000
Number of batteries supported1
Wireless range100 m
Operating frequency2400 - 2480 MHz
Standard interfacesUSB, RS-232
Connectivity technologyWired & Wireless
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
BuzzerYes
CertificationIEC 62471 Class 1 LED
Product colorBlack, Yellow
Protection featuresShock resistant, Water resistant
International Protection (IP) codeIP65
Cables includedRS-232
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height212 mm
Weight380 g

Related product manuals