Motion Features
Product Reference Guide
287
Motion Features
Motionless Timeout
This setting specifies the amount of time that the reader takes to assume
that it is in a motionless condition. The range for this setting is from 500
msec to 25.5 seconds, in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5
= 0005 = 00, 5 = 050, 20 = 200, etc.
3. Go to
page 206 and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
4. Scan the bar code: SELECT MOT
I
ONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix D, Key-
pad
representing the duration which was determined in the steps
above. You will hear a two-beep indica
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See Table 47 for examples of how to set this
feature.
Table 47. Motionless Timeout Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
500ms 1 sec. 10 sec 9,900ms (9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to yield
two digits
)
005 010 100 250
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT MOTIONLESS TIMEOUT SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘5’ ‘0’, ‘1’ and ‘0’ ‘1’, ‘0’, and ‘0’ ‘2’, ‘5’, and ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic PowerScan PBT9500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PBT9500 and is the answer not in the manual?

Datalogic PowerScan PBT9500 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength680 nm
Sensor typeLaser
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle0 - 40 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supported-
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, MaxiCode, Micro QR Code, QR Code
Battery life10 h
Charging time4 h
Battery capacity2150 mAh
Power source typeBattery
Number of reads per charge30000
Number of batteries supported1
Wireless range100 m
Operating frequency2400 - 2480 MHz
Standard interfacesUSB, RS-232
Connectivity technologyWired & Wireless
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
BuzzerYes
CertificationIEC 62471 Class 1 LED
Product colorBlack, Yellow
Protection featuresShock resistant, Water resistant
International Protection (IP) codeIP65
Cables includedRS-232
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height212 mm
Weight380 g