ENTER/EXIT PROGRAMMING MODE READING PARAMETERS
104
POWERSCAN™ PD/PM96XX
Good Read Beeper Volume / Vibration
Selects the beeper volume (loudness) upon a good read beep. There are three select-
able volume levels.
In addition to three selectable volume levels, the user can also activate a vibration feed-
back for good read.
Vibration Feedback for Good Read
$CBPVO00
Good Read Beeper Volume = Beeper Off
Good Read Beeper Volume = Low
$CBPVO01
$CBPVO02
Good Read Beeper Volume = Medium
Good Read Beeper Volume = High
$CBPVO03
$CVBGE01
Vibration Feedback for Good Read = Enable Vibration
Vibration Feedback for Good Read = Disable Vibration
$CVBGE00