ENTER/EXIT PROGRAMMING MODE READING PARAMETERS
106
POWERSCAN™ PD/PM96XX
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following
a good read. The good read LED on time can be set within a range of 100 milliseconds to
25,500 milliseconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps
the LED on until the next trigger pull.
See
page 298 in “References” for detailed instructions and examples for setting this fea-
ture.
$CLAGL00
Good Read LED Duration Setting =
Keep LED on until next trigger pull
Select Good Read LED Duration Setting
$CLAGL
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by three digits from the Alpha-
numeric characters in Appendix D, Keypad repre-
senting your desired character(s). End by scanning
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
003 = Good Read LED stays on for 300 msec.
NOTE: Indicators are dimmed during sleep.

Table of Contents

Other manuals for Datalogic PowerScan PD9630-HP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PD9630-HP and is the answer not in the manual?

Datalogic PowerScan PD9630-HP Specifications

General IconGeneral
BrandDatalogic
ModelPowerScan PD9630-HP
CategoryBarcode Reader
LanguageEnglish

Related product manuals