M7/M7L/M7LT Modular Satellite Modem Maintenance
M7/M7L/M7LT - Rev. 0.05 3-75
High Speed Serial Interface Parameters
Representation
Type
Entry
Description
ESC Async DSR
Force Active
Selection
0 = Normal, 1 = Force
Active
ESC DRS line control
MCC Mode
Full Access
Selection
0 = Disable
1 = Read Only
2 = Full Access
Activates the Modem Control
Channel (MCC)
Any selection other than Disabled
makes other menu selection
below visible
MCC Protocol
M7 Binary Packet
Selection
0 = M7 Binary Packet
1 = M500 AUPC Packet
Sets the Protocol of the MCC
MCC Send Address
1
Numeric
0 to 255, 255 = Global
Sets the Send Address of the
MCC
MCC Rcv Address
1
Numeric
0 to 254
Sets the Rcv Address of the
MCC
MCC Activity
None
Selection
0 = None
1 = Beep
2 = Blink Online Lamp
3 = Beep & Blink Online
Lamp
Sets the front panel indication on
MCC activity.
Event Send Clock Alarm
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the
change in status of the Send
Clock activity alarm
Event Send Data Alarm
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the
change in status of the Send
Data activity alarm
Event Rcv Data Alarm
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the
change in status of the Rcv Data
activity alarm
Event Backward Alarm
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the
change in status of the Backward
alarm
Event BER Loss Alarm
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the
change in status of the BER Loss
alarm
Event Buffer Slip
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the
change in status of the Buffer
Slip alarm
Event Minor Alarm
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the activity
of any Minor alarms
Event Major Alarm
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the activity
of any Major alarms
Event Test Active
Do Not Log
Selection
0 = Do Not Log
1 = Log
2 = Log & Send Alert
Selects whether to log the status
of the Test Active alarm