M7/M7L/M7LT Modular Satellite Modem Maintenance
M7/M7L/M7LT - Rev. 0.05 3-77
High Speed Serial Interface Parameters
Representation
Type
Entry
Description
Test BER Sync Loss
0
Read Only
Enter to restart test
Measurement of the number of
sync losses in the active test if
‘‘Test Rcv BER’ is active
Test BER Errors
15
Read Only
Enter to restart test
Measurement of the number of
bit errors in the active test if ‘Test
Rcv BER’ is active
Test BER Bits
2.853E9
Read Only
Enter to restart test
Total Bits in active test
measurement if ‘Test Rcv BER’ is
active
Test BER EFS
94.35%
Read Only
Enter to restart test
Error free seconds in the active
test measurement if ‘Test Rcv
BER’ is active
Test BER Erred Sec
15
Read Only
Enter to restart test
Errored seconds in the active test
measurement if ‘Test Rcv BER’ is
active
Test BER Total Sec
8485
Read Only
Enter to restart test
Total seconds in the active test
measurement if ‘Test Rcv BER’ is
active
Test Send Bit Offset
0 PPM
Read Only
N/A
Monitor of the frequency offset of
the incoming bit clock reference
to the internal modem reference
standard.
Test Rcv Bit Offset
0 PPM
Read Only
N/A
Monitor of the frequency offset of
the bit clock recovered from the
satellite, reference to the internal
modem reference standard.
Feature Options
None
Read Only
N/A
Feature Activation
00000000000000000000
Numeric
20 characters
Allows entry of a Feature code to
activate new features.