EasyManuals Logo

DeLaval MPCII User Manual

DeLaval MPCII
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Operation
DeLaval milking point controller MPCII
94381001.pdf2006-07-20
–EF–
Enter function
After 3 seconds the display shows:
PASSWD
Enter password 6285
321
Auto take-off
1 (0 = no, 1 = yes)
If processor ver 4.x this must be set
locally on every MPCII
↑ =
↑ * =
322
Sweep
0 (0 = no, 1 = yes)
323
Alfa Dast
0 (0 = no, 1 = yes)
324
Auto-forced high vacuum delay
0 (0 = no, 1 = yes)
325
Direct input of milk weight after take-off
0 (0 = no, 1 = yes)
326
Milk yield presentation
0 (as kg = 0 (default), as pounds = 1)
(former F90, can only be changed in
stand-by mode)
327
Pulsation during take-off
0 (0 = pulsation, 1 = no pulsation)
328
Regulator block option
0 (0 = no, 1 = yes)
329
Milk meter type
1 (0 = MM15, 1 = MM25, 2 = FI2, 3 = FI5)
330
Regulator block shut-off in standby mode
0 (0 = shut-off after 90 min., 1 = always
activated)
331
ID-mode
1 (0 = ID-mode 1, 1 = ID-mode 2)