EasyManuals Logo

DeLaval MPCII User Manual

DeLaval MPCII
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
Operation
DeLaval milking point controller MPCII
94381001.pdf2006-07-20
New address of the MPCII:
If you now want to change the address,
press 6285 ↑ and write the new address.
F82 – Local cleaning mode
System and stand-alone
Pressing F, 8, 2, and ↑ on the MPCII forces
the MPCII to cleaning mode (emergency
function).
Note! Pulsation ratio always default 65/35
during cleaning mode.
Besides the ordinary set of functions in the
MPCII program, following four functions
(F83, F84, F85, and F86) are special for
Tandem.
F83 – Deactivate entrance photocell
Tandem System
This function will deactivate the photocell at
the main entrance.
The function can be used when a cow is not
used to the gates. It can also be used when
someone wants to walk through the gates,
and leave them open.
If F83 ↑ is pressed on an ordinary MPCII,
only the side where the MPCII is located,
will be deactivated. If F83 ↑ is pressed on
the special MPCII, both sides will be
deactivated. The adjoining display is shown
on the MPCII, when function F83 is used.
The main gate will not close after a cow
which has passed the photocell.
To activate the photocell again, just press
F83 ↑.
77(94)