EasyManuals Logo

DeLaval MPCII User Manual

DeLaval MPCII
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
Operation
DeLaval milking point controller MPCII
94381001.pdf2006-07-20
F88 – Calibration
The calibration weight.
Example:
1.
2.
3.
4.
System and stand-alone
Pressing F, 8, 8, and ↑ in standby mode
sets the MPCII into calibration mode.
- Interrupt by pressing F ↑
After removal of the calibration cup the
MPCII enters check calibration mode
automatically. Apply the test cup and
compare the weight on the display to the
test cup weight. The two weights must not
differ more than ± 0.08.
Only used when the milk meter should be
calibrated by a DeLaval serviceman.
F89 – Check calibration
System and stand-alone
Pressing F, 8, 9, and ↑ in standby mode
makes the MPCII ready for checking the
calibration. The milk meter is checked for
accuracy.
- Finish, or interrupt by pressing F ↑
Check calibration is only used by a DeLaval
serviceman.
F91 – Set default parameters
System and stand alone
New set default parameters. Keeps address
and calibration value.
F94 – Liner data
System, not ver 6.20
The "Liner data" can be reset on a particular
MPCII.
80(94)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeLaval MPCII and is the answer not in the manual?

DeLaval MPCII Specifications

General IconGeneral
BrandDeLaval
ModelMPCII
CategoryController
LanguageEnglish