Operation
DeLaval milking point controller MPCII
94381001.pdf2006-07-20
F97 – BOOT version
This function shows the BOOT version
number. Read-only.
F98 – Application version
This function shows the application program
version of the active application.
F100 – Cow not ready milked
Only rotary
If a cow has not been milked completely
during one revolution, she may stay on the
Rotary for an additional revolution.
- Program F100 ↑ before the cow has
reached the position where milk yield will
be confirmed (see chapter General
description, position 3), and she will
continue to be milked during a second
round.
- If, however, F100 ↑ is pressed after
position 3, the cow will continue to be
milked during a second round. But, when
milk yield is confirmed at position 3 the
second time, milk yield from the first
round will be sent to function 3:7:3,
PROBLEM YIELDS (as Already milked)
and appear on the Problem List. Milk yield
from the second round will however be
stored normally.
F101 – Stop of platform
This function will stop the rotation of the
platform when the cow reaches the confirm
place, by sending a no cluster removal
signal from the special MPCII via a relay to
the drive control system. A function that can
be used for e.g. removal of a cows kick
protector before exit. It is deactivated with
F101 if the kick protector has been removed
before confirm place.
For connection see Installation menu.
82(94)