Operation
DeLaval milking point controller MPCII
94381001.pdf2006-07-20
332
Parlour type
(1 = Herringbone, 2 = Rotary, 3 = Tandem,
4 = Midi Line)
333
A special flag indicating that the installed
MPCII is a "special MPCII". Is reset by the
processor. For Tandem and Rotary only.
0 (0 = milking point MPCII, 1 = special
MPCII flag)
334
Pulsator type
1 (0 = No EP, 1 = EP100, 2 = EP50, 3 =
EP60, 4 = EP70)
F63 – General parameters
Stand-alone
–EF–
Enter function
After 3 seconds the display shows:
PASSWD
Enter password 6285
311 311
Cow 0/1 Cow 0/1
Yield 0/1 Yield 0/1
Flow 0/1 Flow 0/1
Time 0/1 Time 0/1
311
Display mode
Cow/yield
(COW: 0 = No, 1 = Yes;
YIELD: 0 = No, 1 = Yes;
FLOW: 0 = No, 1 = Yes;
TIME: 0 = No, 1 = Yes)
321
Pre-milking time
120 seconds (60-240)
322
Forced vacuum time
30 sec (0-150)
323
Post-milking time
20 sec (0-40)
324
Take-off delay
35 /10 sec (0-9.9)
68(94)