EasyManua.ls Logo

Dell EMC PowerProtect DD9900 - Configure Serial over LAN (SOL); Idrac Settings > User Configuration

Dell EMC PowerProtect DD9900
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note: The default password is the system serial number. The system serial number is
always on the service tag at the front of the system, and on the PSNT tag attached
to the rear handle of the chassis if the system has a rear-mounted PSNT tag.
Figure 65 iDRAC Settings > User Configuration
After you finish
Use iDRAC to power the system on and off remotely on page 91 descibes how to power the
system on and off with iDRAC.
The
DD OS, PowerProtect DD Virtual Edition, and PowerProtect DD Management Center Security
Configuration Guide
provides additional information about accessing security settings in iDRAC.
Configure serial over LAN (SOL)
About this task
The PowerProtect system provides the ability to access the serial console through the iDRAC
interface.
Configuring SOL is optional.
If SOL is already enabled on the system, no further action is required.
CAUTION
Do not use iDRAC to change the storage configuration, system settings, or BIOS
settings, as making changes will impact system functionality. Contact Support if changes are
required in any of these areas.
CAUTION Enabling SOL disables the serial console.
Procedure
1. In a web browser, type the iDRAC IP address specified during iDRAC configuration.
2. Login with the user name root. The default password is the system serial number on the
PSNT.
3. Select Configuration > BIOS Settings > Serial Communications.
4. Verify the following values are configured, and specify any that are not set as listed:
Configure System for Use
Dell EMC PowerProtect DD9900 System Installation Guide 73

Table of Contents

Related product manuals