Configuring System Information 169
Figure 6-40. Optical Transceiver Diagnostics
The Optical Transceiver Diagnostics
page contains the following fields:
Port
— The port IP address on which the cable is tested.
Temperature
— The temperature (C) at which the cable is operating.
Voltage
— The voltage at which the cable is operating.
Current
— The current at which the cable is operating.
Output Power
— The rate at which the output power is transmitted.
Input Power
— The rate at which the input power is transmitted.
Transmitter Fault
— Indicates if a fault occurred during transmission.
Loss of Signal
—Indicates if a signal loss occurred in the cable.
Data Ready
—Indicates the transceiver has achieved power up and data is ready.
Displaying Optical Transceiver Diagnostics Test Results Table
1
Open the
Optical Transceiver Diagnostics
page.
2
Click
Show All
to run the test and open the
Virtual Cable Test Results Table
page.