Table 41. HTTP Device n Settings details (continued)
Option Description
Vlan Priority Shows the Vlan Priority for the HTTP device.
DHCP Enables or disables DHCP for this HTTP device. This option is set to Enabled by default.
IP Address Specifies IP address for the HTTP device.
Subnet Mask Specifies subnet mask for the HTTP device.
Gateway Specifies gateway for the HTTP device.
DNS info via DHCP Enables or disables DNS Information from DHCP. This option is set to Enabled by default.
Primary DNS Specifies the primary DNS server IP address for the HTTP Device.
Secondary DNS Specifies the secondary DNS server IP address for the HTTP Device.
URI Obtain URI from the DHCP server if not specified
TLS Authentication
Configuration
Specifies the option for TLS authentication configuration.
Table 42. ISCSI Device1 Settings screen details
Option Description
Connection 1 Enables or disables the iSCSI connection. This option is set to Disabled by default.
Connection 2 Enables or disables the iSCSI connection. This option is set to Disabled by default.
Connection 1 Settings Enables you to control the configuration for the iSCSI connection.
Connection 2 Settings Enables you to control the configuration for the iSCSI connection.
Connection Order Enables you to control the order for which the iSCSI connections will be
attempted.
Table 43. TLS Authentication Configuration screen details
Option Description
TLS Authentication Mode View or modify the device's boot TLS Authentication Mode. This option is set to One
Way by default. None means the HTTP server and the client will not authenticate each
other for this boot.
Root Certificate Configuration Import, delete, or export the root certificate.
Table 44. NVMe-oF SubSystem Settings screen details
Option Description
NVMe-oF SubSystem n (n = 1 to 4) Enables or disables NVMe-oF SubSystem. This option is set to Disabled by
default.
NVMe-oF SubSystem n Settings (n = 1
to 4)
Enables you to control the configuration of the NVMe-oF SubSystem, if Enabled.
Table 45. NVMe-oF SubSystem n Settings
Option Description
Interface NIC interface used for NVMe-oF connections. This option is set to Embedded
NIC 1 Port 1 Partition 1 by default.
Transport Type This field sets the value of transport type for NVMe-oF connection. This option is
set to TCP by default.
Protocol This field sets the value of protocol type for NVMe-oF connection. This option is
set to IPv4 by default.