Chapter 7 Application Examples
7-11
7_
Wiring the inputs and outputs of ASRTU-EC16AP1TA
As the wiring in the above figure shows, please connect the common terminal S/S to 24V, the C0 terminal
to 0V, the input point X0.0 to the output point Y0.0, and the input point X0.1 to the output point Y0.1.
Setting the network configuration
1. Download and DIADesigner-AX software from Delta official website, install it and then start the
software.
2. After clicking “New Project…” in the open software interface, select the “Standard project” template
and then type a project name and storage location in the “New Project” window as below.