GAVIN-6C Instruction Manual
- 34 -
it will adjust the aileron operation in the negative direction. If the value is
positive, it will adjust the aileron operation in the positive direction. The default
is 0.
THR▶RUD: This parameter is used to set the mixing rate (percentage) from
throttle channel to rudder channel. Values: -100~100. If the value is negative,
it will adjust the rudder operation in the negative direction. If the value is
positive, it will adjust the rudder operation in the positive direction. The default
is 0.
THR▶ELE: This parameter is used to set the mixing rate (percentage) from
throttle channel to elevator channel. Values: -100~100. If the value is negative,
it will adjust the elevator operation in the negative direction. If the value is
positive, it will adjust the elevator operation in the positive direction. The
default is 0.
Veer to Elevator Mixing [Veer▶ELE]
Corresponding model type: airplane, general
This function mixes aileron and rudder to elevator.
The mixing amounts from aileron and rudder to elevator can be set separately for
left and right as two independent settings.
Setting Method:
1. In the Mix Set setting interface, press UP or DOWN key to select Veer▶ELE
Mix, and then press ENT key to enter the setting interface.