System administration Schedule system maintenance tasks
IX10 User Guide
840
l
If Duration window is set to any value other than to Immediately or 24 hours,
the maintenance tasks will run at a random time during the time allotted for
the duration window.
l
If Duration window is set to one or more hours, the minutes field in Start time
is ignored and the duration window will begin at the beginning of the specified
hour.
c. For Duration window, select the amount of time that the maintenance tasks will
be run. If Immediately is selected, all scheduled tasks will begin at the exact time
specified in Start time.
d. For Frequency, select whether the maintenance window will be started every day,
or once per week.
n
If Check if Python Out-of-Service is set, the maintenance window will only start if the
Python Out-of-Service is set. See Use Python to set the maintenance window for further
information.
7. If Central Management is disabled, click Device firmware update to instruct the system to
look for any updated device firmware during the maintenance window. If updated firmware is
found, it will then be installed. This options is only available if Central Management is
disabled; see Central management for more information.
8. If Central Management is disabled, click to enable Modem firmware update to instruct the
system to look for any updated modem firmware during the maintenance window. If updated
firmware is found, it will then be installed. Modem firmware update looks for updated
firmware both on the local device and over the network, using either a WAN or cellular
connection. This options is only available if Central Management is disabled; see Central
management for more information.
9. (Optional) Configure automated checking for device and modem firmware updates:
a. Click to expand Firmware update check.
b. Device firmware update check is enabled by default. This enables the automated
checking for device firmware updates.
c. Modem firmware update check is enabled by default. This enables the automated
checking for modem firmware updates.
d. For Frequency, select how often automated checking for device and modem firmware
should take place. Allowed values are Daily, Weekly, and Monthly. The default is Daily.
10. Click Apply to save the configuration and apply the change.
Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX10
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>