Diagnostics Configure options for the event and system logs
IX10 User Guide
899
iii. To change the status interval:
(config)> system log event dhcpserver status_interval value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set the status interval to ten minutes, enter either 10m or 600s:
(config)> system log event dhcpserver status_interval 600s
(config)>
6. (Optional) See Configure syslog servers for information about configuring remote syslog
servers to which log messages will be sent.
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.